Human SPDL1 (Spindle apparatus coiled-coil domain-containing protein 1) ELISA Kit

CAT:
855-ELK0396-02
Size:
96 Tests
  • Availability: 24/48H Stock Items & 2 to 6 Weeks non Stock Items.
  • Dry Ice Shipment: No
Human SPDL1 (Spindle apparatus coiled-coil domain-containing protein 1) ELISA Kit - image 1

Human SPDL1 (Spindle apparatus coiled-coil domain-containing protein 1) ELISA Kit

  • Description :

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human SPDL1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human SPDL1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human SPDL1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human SPDL1 in the samples is then determined by comparing the OD of the samples to the standard curve.
  • Product Name Alternative :

    CCDC99; SPDLY; Arsenite-related gene 1 protein; Coiled-coil domain-containing protein 99; Rhabdomyosarcoma antigen MU-RMS-40.4A
  • Reactivity :

    Human
  • Field of Research :

    Immunology & Inflammation
  • Assay Type :

    Sandwich
  • Assay Principle :

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human SPDL1. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human SPDL1. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human SPDL1, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human SPDL1 in the samples is then determined by comparing the OD of the samples to the standard curve.
  • Assay Performance Time :

    3.5h
  • Standard :

    20 ng/mL
  • Sample Type :

    Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids
  • Detection Range :

    0.32-20 ng/mL
  • Sensitivity :

    0.11 ng/mL