Human IA-2 Ab (Insulinoma associated antigen 2 Autoantibody) ELISA Kit

CAT:
855-ELK0858-02
Size:
96 Tests

For Laboratory Research Only. Not for Clinical or Personal Use.

  • Availability: 24/48H Stock Items & 2 to 6 Weeks non Stock Items.
  • Dry Ice Shipment: No
Human IA-2 Ab (Insulinoma associated antigen 2 Autoantibody) ELISA Kit - image 1

Human IA-2 Ab (Insulinoma associated antigen 2 Autoantibody) ELISA Kit

  • Description :

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human IA-2 Ab. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human IA-2 Ab. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human IA-2 Ab, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human IA-2 Ab in the samples is then determined by comparing the OD of the samples to the standard curve.
  • Product Name Alternative :

    IA2 Ab
  • Reactivity :

    Human
  • Field of Research :

    Signal transduction
  • Assay Type :

    Sandwich
  • Assay Principle :

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human IA-2 Ab. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human IA-2 Ab. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human IA-2 Ab, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human IA-2 Ab in the samples is then determined by comparing the OD of the samples to the standard curve.
  • Assay Performance Time :

    3.5h
  • Standard :

    4000 U/mL
  • Sample Type :

    Tissue homogenates, cell lysates and other biological fluids
  • Detection Range :

    62.5-4000 U/mL
  • Sensitivity :

    26.8 U/mL

Featured Selection

Popular Products

Discover our most sought-after biotechnology products, trusted by researchers worldwide