Human SCXB (Scleraxis Homolog B) ELISA Kit

CAT:
855-ELK7158-01
Size:
48 Tests

For Laboratory Research Only. Not for Clinical or Personal Use.

  • Availability: 24/48H Stock Items & 2 to 6 Weeks non Stock Items.
  • Dry Ice Shipment: No
Human SCXB (Scleraxis Homolog B) ELISA Kit - image 1

Human SCXB (Scleraxis Homolog B) ELISA Kit

  • Description :

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human SCXB. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human SCXB. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human SCXB, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human SCXB in the samples is then determined by comparing the OD of the samples to the standard curve.
  • Product Name Alternative :

    SCX; BHLHA41; BHLHA48; SCXA; Basic Helix-Loop-Helix Transcription Factor Scleraxis; Class A basic helix-loop-helix protein 48
  • Reactivity :

    Human
  • Field of Research :

    Signal transduction
  • Assay Type :

    Sandwich
  • Assay Principle :

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human SCXB. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human SCXB. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human SCXB, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human SCXB in the samples is then determined by comparing the OD of the samples to the standard curve.
  • Assay Performance Time :

    3.5h
  • Standard :

    10 ng/mL
  • Sample Type :

    Tissue homogenates, cell lysates and other biological fluids
  • Detection Range :

    0.16-10 ng/mL
  • Sensitivity :

    0.054 ng/mL

Featured Selection