Human EAAT3 (Excitatory Amino Acid Transporter 3) ELISA Kit
For Laboratory Research Only. Not for Clinical or Personal Use.
- Availability: 24/48H Stock Items & 2 to 6 Weeks non Stock Items.
- Dry Ice Shipment: No


Human EAAT3 (Excitatory Amino Acid Transporter 3) ELISA Kit
Description :
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human EAAT3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human EAAT3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human EAAT3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human EAAT3 in the samples is then determined by comparing the OD of the samples to the standard curve.Product Name Alternative :
SLC1A1; EAAC1; Solute Carrier 1 Member 1; Sodium-dependent glutamate/aspartate transporter 3; Excitatory amino-acid carrier 1; Neuronal and epithelial glutamate transporterUniProt :
P43005Reactivity :
HumanField of Research :
Neuro scienceAssay Type :
SandwichAssay Principle :
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human EAAT3. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human EAAT3. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human EAAT3, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human EAAT3 in the samples is then determined by comparing the OD of the samples to the standard curve.Assay Performance Time :
3.5hStandard :
20 ng/mLSample Type :
Tissue homogenates and other biological fluids.Detection Range :
0.32-20 ng/mLSensitivity :
0.119 ng/mL

