Human MYH10 (Myosin Heavy Chain 10, Non Muscle) ELISA Kit

CAT:
855-ELK3060-01
Size:
48 Tests
  • Availability: 24/48H Stock Items & 2 to 6 Weeks non Stock Items.
  • Dry Ice Shipment: No
Human MYH10 (Myosin Heavy Chain 10, Non Muscle) ELISA Kit - image 1

Human MYH10 (Myosin Heavy Chain 10, Non Muscle) ELISA Kit

  • Description :

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MYH10. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MYH10. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MYH10, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MYH10 in the samples is then determined by comparing the OD of the samples to the standard curve.
  • Product Name Alternative :

    NMMHCB; Cellular myosin heavy chain, type B; Myosin heavy chain, non-muscle IIb
  • UniProt :

    P35580
  • Reactivity :

    Human
  • Field of Research :

    Metabolic pathway
  • Assay Type :

    Sandwich
  • Assay Principle :

    The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Human MYH10. Standards or samples are added to the appropriate microtiter plate wells then with a biotin-conjugated antibody specific to Human MYH10. Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Human MYH10, biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Human MYH10 in the samples is then determined by comparing the OD of the samples to the standard curve.
  • Assay Performance Time :

    3.5h
  • Standard :

    10 ng/mL
  • Sample Type :

    Serum, plasma and other biological fluids.
  • Detection Range :

    0.16-10 ng/mL
  • Sensitivity :

    0.055 ng/mL